Role of harmonics and subharmonics in peripheral pulse analysis


1 Department of Bio-Medical Engineering, MGM College of Engineering and Technology, Navi Mumbai, Maharashtra, India
2 Department of Bio-Technology, MGM Institute of Health Sciences, Navi Mumbai, Maharashtra, India
3 Department of Medicine, MGM Institute of Health Sciences, Navi Mumbai, Maharashtra, India

Correspondence Address:
Dr. G D Jindal
Department of Bio-Medical Engineering, MGM College of Engineering and Technology, Kamothe, Navi Mumbai, Maharashtra.
India
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/mgmj.mgmj_47_20

Rights and Permissions

Elastic compliance of the blood vessels contributes high-frequency components in the peripheral pulse, which are analyzed with the help of the power spectral density of the signal. The frequency corresponding to heart rate in a subject is called his fundamental harmonic or first harmonic, frequency twice the heart rate is called second harmonic, and so on. The contribution of these harmonics is assessed by performing Fourier transform on the peripheral blood volume or flow pulse signal for sufficient duration, which yields power spectral density of the peripheral pulse. Dedicated software, known as pulse harmonic analyzer, has also been developed for performing harmonic analysis of the peripheral signal. It not only yields a contribution of higher harmonics in the pulse but also subharmonics (frequencies smaller than the heart rate of the subject). Researchers have observed suppression of second harmonics in subjects aging more than 30 years, suppression of high-frequency components in the power spectral density of the pulse in the coronary artery disease and enhancement of the first harmonic in hypertensives and subjects susceptible to diabetes during the past four decades. Subharmonic components are observed to be related to variability in heart rate, pulse volume, and pulse morphology, which has the potential to become a method of choice for continuous real-time variability monitoring in intensive care units. These observations are reviewed in this paper briefly.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed129    
    Printed8    
    Emailed0    
    PDF Downloaded24    
    Comments [Add]    

Recommend this journal